{"product_id":"pjp36100u31a","title":"PJP36100U31A","description":"\u003cp data-start=\"88\" data-end=\"486\"\u003eThe Schneider Electric \/ Square D PJP36100U31A is a three-phase molded case circuit breaker designed to provide dependable protection for industrial and commercial power distribution systems. Part of the PowerPacT P-frame family, this breaker is built for high-capacity electrical applications where reliable overload and short-circuit protection are required. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"488\" data-end=\"827\"\u003eRated for 1000 Amps, the PJP36100U31A is suitable for use on systems up to 600 VAC. Its 3-pole configuration makes it appropriate for three-phase installations, while its molded case construction provides a durable, compact solution for panelboard, switchboard, and equipment-level circuit protection. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"829\" data-end=\"1204\"\u003eThis unit includes a Micrologic 3.0 electronic trip system, which provides long-time and instantaneous protection functions. These trip features help protect connected equipment from sustained overload conditions and high-current fault events, improving system safety and reducing the risk of damage during abnormal operating conditions. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1206\" data-end=\"1576\"\u003eThe PJP36100U31A is an 80% rated breaker supplied with lugs and is commonly used in demanding power distribution environments where high amperage capacity and dependable fault interruption are essential. Its interrupting capacity is rated up to 100 kA at 240 VAC, 65 kA at 480 VAC, and 25 kA at 600 VAC, depending on system voltage. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1578\" data-end=\"1860\"\u003eDesigned under the Schneider Electric \/ Square D PowerPacT platform, this circuit breaker is built for compatibility with industrial electrical distribution equipment and is well-suited for applications requiring a 1000A, 3-pole protective device with electronic trip functionality.\u003c\/p\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1926\" data-end=\"2802\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1926\" data-end=\"1953\"\u003e\n\u003ctr data-start=\"1926\" data-end=\"1953\"\u003e\n\u003cth data-start=\"1926\" data-end=\"1942\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"1942\" data-end=\"1953\" data-col-size=\"md\" class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1964\" data-end=\"2802\"\u003e\n\u003ctr data-start=\"1964\" data-end=\"2012\"\u003e\n\u003ctd data-start=\"1964\" data-end=\"1979\" data-col-size=\"sm\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"1979\" data-end=\"2012\"\u003eSchneider Electric \/ Square D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2013\" data-end=\"2043\"\u003e\n\u003ctd data-start=\"2013\" data-end=\"2027\" data-col-size=\"sm\"\u003ePart Number\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2027\" data-end=\"2043\"\u003ePJP36100U31A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2044\" data-end=\"2094\"\u003e\n\u003ctd data-start=\"2044\" data-end=\"2063\" data-col-size=\"sm\"\u003eProduct Category\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2063\" data-end=\"2094\"\u003eMolded Case Circuit Breaker\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2095\" data-end=\"2133\"\u003e\n\u003ctd data-start=\"2095\" data-end=\"2112\" data-col-size=\"sm\"\u003eProduct Family\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2112\" data-end=\"2133\"\u003ePowerPacT P-Frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2134\" data-end=\"2154\"\u003e\n\u003ctd data-start=\"2134\" data-end=\"2147\" data-col-size=\"sm\"\u003eFrame Type\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2147\" data-end=\"2154\"\u003ePJP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2155\" data-end=\"2181\"\u003e\n\u003ctd data-start=\"2155\" data-end=\"2171\" data-col-size=\"sm\"\u003eRated Current\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2171\" data-end=\"2181\"\u003e1000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2182\" data-end=\"2210\"\u003e\n\u003ctd data-start=\"2182\" data-end=\"2199\" data-col-size=\"sm\"\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2199\" data-end=\"2210\"\u003e600 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2211\" data-end=\"2244\"\u003e\n\u003ctd data-start=\"2211\" data-end=\"2233\" data-col-size=\"sm\"\u003ePhase Configuration\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2233\" data-end=\"2244\"\u003e3-Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2245\" data-end=\"2268\"\u003e\n\u003ctd data-start=\"2245\" data-end=\"2263\" data-col-size=\"sm\"\u003eNumber of Poles\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2263\" data-end=\"2268\"\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2269\" data-end=\"2299\"\u003e\n\u003ctd data-start=\"2269\" data-end=\"2281\" data-col-size=\"sm\"\u003eTrip Unit\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2281\" data-end=\"2299\"\u003eMicrologic 3.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2300\" data-end=\"2346\"\u003e\n\u003ctd data-start=\"2300\" data-end=\"2318\" data-col-size=\"sm\"\u003eTrip Technology\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2318\" data-end=\"2346\"\u003eElectronic \/ Solid-State\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2347\" data-end=\"2392\"\u003e\n\u003ctd data-start=\"2347\" data-end=\"2364\" data-col-size=\"sm\"\u003eTrip Functions\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2364\" data-end=\"2392\"\u003eLong-Time, Instantaneous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2393\" data-end=\"2420\"\u003e\n\u003ctd data-start=\"2393\" data-end=\"2407\" data-col-size=\"sm\"\u003eRating Type\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2407\" data-end=\"2420\"\u003e80% Rated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2421\" data-end=\"2462\"\u003e\n\u003ctd data-start=\"2421\" data-end=\"2438\" data-col-size=\"sm\"\u003eMounting Style\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2438\" data-end=\"2462\"\u003eUnit Mount \/ Bolt-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2463\" data-end=\"2487\"\u003e\n\u003ctd data-start=\"2463\" data-end=\"2479\" data-col-size=\"sm\"\u003eTerminal Type\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2479\" data-end=\"2487\"\u003eLugs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2488\" data-end=\"2564\"\u003e\n\u003ctd data-start=\"2488\" data-end=\"2510\" data-col-size=\"sm\"\u003eInterrupting Rating\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2510\" data-end=\"2564\"\u003e100 kA @ 240 VAC, 65 kA @ 480 VAC, 25 kA @ 600 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2565\" data-end=\"2589\"\u003e\n\u003ctd data-start=\"2565\" data-end=\"2577\" data-col-size=\"sm\"\u003eFrequency\u003c\/td\u003e\n\u003ctd data-start=\"2577\" data-end=\"2589\" data-col-size=\"md\"\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2590\" data-end=\"2634\"\u003e\n\u003ctd data-start=\"2590\" data-end=\"2603\" data-col-size=\"sm\"\u003eWire Range\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2603\" data-end=\"2634\"\u003e3\/0 AWG to 500 kcmil, Al\/Cu\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2635\" data-end=\"2697\"\u003e\n\u003ctd data-start=\"2635\" data-end=\"2649\" data-col-size=\"sm\"\u003eApplication\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2649\" data-end=\"2697\"\u003eIndustrial and Commercial Power Distribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2698\" data-end=\"2757\"\u003e\n\u003ctd data-start=\"2698\" data-end=\"2716\" data-col-size=\"sm\"\u003eProtection Type\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2716\" data-end=\"2757\"\u003eOverload and Short-Circuit Protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2758\" data-end=\"2802\"\u003e\n\u003ctd data-start=\"2758\" data-end=\"2771\" data-col-size=\"sm\"\u003eCompliance\u003c\/td\u003e\n\u003ctd data-start=\"2771\" data-end=\"2802\" data-col-size=\"md\"\u003eUL 489, CSA, IEC\/EN 60947-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Schneider Electric","offers":[{"title":"Original Packaging","offer_id":49264322117859,"sku":null,"price":9500.0,"currency_code":"USD","in_stock":true},{"title":"Used","offer_id":49264322150627,"sku":null,"price":9500.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0674\/2602\/5699\/files\/schneider-electric-pjp36100u31a-1244541661.png?v=1781544342","url":"https:\/\/www.replacenc.com\/products\/pjp36100u31a","provider":"Replace Industrial","version":"1.0","type":"link"}